Skip links

Wax Recovery System

High-performance wax recovery system with integrated centrifuge technology, designed to reclaim and purify de-waxed material for efficient reuse in investment casting.

Brochure

Download our document to see specific data of the service and how we work.

Wax Recovery System

Let’s Start Work Together

Please feel free to contact us. We will get back to you with 1-2 business days. Or just call us now.

0821-428 2039, +91 97402 07101

sales@incastt.com

64/E7, Hootagalli Industrial Area, Mysore – 570018.

Contact us Now!

Engineered for Efficiency. Designed for Sustainability.

The WRS – CEN 400 UF is a fully integrated wax recovery system with centrifuge technology, designed to reclaim high-quality wax from the de-waxing process—reducing input costs while maintaining the integrity and usability of recovered wax for pattern applications.

Built for durability and performance, the WRS unit is ideal for high-throughput foundry environments seeking cost-effective and eco-conscious solutions.

Key Features:

High-efficiency centrifuge for wax purification

Dual-stage wax cleaning: preparation + centrifugation

Maintains wax temperature below 100°C for quality retention

Continuous output: 1 kg of clean wax per minute

Fully automated control with preset factory parameters

Robust, industrial-grade build with intuitive interface

Parameter Specification
Model WRS – CEN 400 UF
Machine Weight 1400 kg
Power Supply 3 Phase, 415V AC, 50/60 Hz
Control Panel Power MCB – 40A, 4P (ABB), Incomer: 6 sq.mm x 4 core cable
System Output 1 kg clean wax per minute
Operating Temperature (WRS) Set to 95°C (max temperature < 100°C)
Operating Temperature (Centrifuge) 5°C higher than WRS (approx. 100°C)
Wax Pump Pressure Regulated to 2 Bar
Centrifuge Motor Electric Motor with VFD (1.5kW, 415V AC)
Hot Water Inlet for Priming 1 Litre per minute
Construction Includes Wax Melter, Preparation Tank, Filter, Centrifuge Unit
Sensors & Controllers Level Sensor, Temp. Sensor, Temp. Controller (Selec)
Filtration Stages Preparation Tank + Fine Centrifuge Separation
Heaters 750W Band Heaters
Maintenance Schedule Bi-weekly greasing, weekly O-ring and sensor checks
Compressed Air Requirement 8 mm OD Tube for inlet (FRL)